Ramcro – Security & Sound 2 Conductor 18 AWG BC LSZH Eca
Brand Name:Â | RAMCRO |
Part Number: | R1722 |
Product Type:Â | Ramcro – Security & Sound 2 Conductor 18 AWG BC LSZH Eca |
Specification: | Please refer to the Datasheet on the Manufacturer’s Datasheet |
Warranty: | Manufacturer Standard Warranty |
Description
Ramcro – Security & Sound 2 Conductor 18 AWG BC LSZH Eca
Details:
Ramcro – Security & Sound 2 Conductor 18 AWG BC LSZH Eca
Specifications:
The Ramcro cable is an alternative to the Belden cable
Security & Commercial Audio Cable, 2-18 AWG stranded bare copper conductors with polypropylene insulation, LSZH jacket with ripcord, CPR Eca
Technical Specifications
Product Overview
- Suitable Applications: Intercom/PA Systems, Sound/Audio Systems, Control Systems
Construction Details
- Size: 18
- Stranding: 7×26
- Material: BC – Bare Copper
Insulation
- Material: PP – Polypropylene
- Thickness: 0.2 mm (0.0079 in)
- Insulation Diameter: 1.5 mm (0.059 in)
- Color Code: Black, Red
Outer Jacket
- Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
- Thickness: 0.4 mm (0.016 in)
- Diameter: 4.6 mm (0.18 in)
- Ripcord: Yes
- Table Notes: Ripcord provided under sheath
- Overall Cable Diameter (Nominal): 4 mm (0.16 in)
Electrical Characteristics
Electricals
- Conductor DCR: 21.3 Ohm/km (6.49 Ohm/1000ft)
- Capacitance Cond-to-Cond: 100 pF/m (30 pF/ft)
- Current: 5A
Mechanical Characteristics
Temperature
- Operating: -20°C To +70°C
- Installation: -20°C To +70°C
- Storage: -30°C To +70°C
Bend Radius
- Installation Min. 40 mm (1.6 in)
- Pull Tension: 90 N (20 lbf)
Standards and Compliance
- Environmental Suitability: Indoor – Euroclass Eca, Non-Halogenated
- Flammability / Reaction to Fire: IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- ISO/IEC Compliance: IEC 61034-2 – Smoke Density Min Transmittance = 60%
- CENELEC Compliance: EN 50290-2-20
- European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
- European Directive Compliance: EU Directive 2011/65/EU (RoHS 2)
- UK Regulation Compliance: UKCA Mark