Brand Name:Â | ExTell |
Part Number: | E003SER31 |
Product Type:Â | ExTell – ExTell Galaxy Rack Tower Single Phase External Battery 3 KVA Online UPS PF = 1.0 |
Specification: | Please refer to the Datasheet on the Manufacturer’s Datasheet |
Warranty: | Manufacturer Standard Warranty |
Description
ExTell – ExTell Galaxy Rack Tower Single Phase External Battery 3 KVA Online UPS PF = 1.0
Details:
ExTell – ExTell Galaxy Rack Tower Single Phase External Battery 3 KVA Online UPS PF = 1.0
Specification:
ExTell Galaxy Single Phase Online UPS is the ideal protection and power backup device for your sensitive and critical loads. With a true Double-Conversion online design, Galaxy gives you a pure sinewave output with a Unity Power Factor Load Carrying capacity.
It has a rich LCD Display that provides you all the vital information and has configurable Voltage and Charging current adjustment capability. Backed up with ECO Mode for Energy Saving, Galaxy is a SMART UPS that is Network Manageable by the addition of an external SNMP Card. With an optimized and low THDi and Emergency Power Off Function, Galaxy guarantees full time protection and zero switching time.
Features
- Unity Power Factor
- True Double Conversion
- EPO Function
- Network Manageable
- ECO Mode for Energy Saving
- Low THDi to reduce power system pollution
- Adjustable charging current
TECHNICAL SPECIFICATIONS
- Model: E003GER31
- Phase: Single phase with ground
- Capacity: 3000 VA / 3000 W
INPUT
- Nominal Voltage: 100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
- Voltage Range: 55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% Load, 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% Load
- Frequency Range: 40Hz ~ 70Hz
- Harmonic Distortion(THDi): ≦5% @ Nominal Input Voltage
- Power Factor: ≧99 @ Nominal Voltage (100% load)
OUTPUT
- Output Voltage: 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode): ± 1%
- Frequency Range (Synchronized Range): 57 ~ 63 Hz or 47 ~ 53 Hz
- Frequency Range (Batt. Mode): 0Hz ± 0.1Hz or 50 Hz ± 0.1Hz
- Current Crest Ratio: 3:1 (max.)
- Harmonic Distortion: ≦ 2 % THD (Linear Load); ≦ 4 % THD (Non-Linear Load)
- Transfer Time – AC Mode to Battery Mode: Zero
- Transfer Time – Inverter to Bypass: 4 ms (Typical)
- Waveform (Batt. Mode): Pure Sinewave
EFFICIENCY
- AC Mode: ≧91% @ Full Charged Battery
- ECO Mode: ≧ 96% @ Full Charged Battery
- Battery Mode: ≧90%
BATTERY
- Battery Type: 12 V / 9 AH – 12 V / 7 AH
- Numbers: 6
- Typical Recharge Time: 3 Hours Recover to 95% Capacity for Internal Battery@ 2A Charging Current
- Charging Current: 100/110/115/120 /127 VAC Models: Default 2A, Max. 8A Adjustable
- 200/208/220/230/240 VAC Models: Default 2A, Max. 12A Adjustable
- Charging Voltage: 27.4 VDC ± 1% – 1 VDC ± 1%