ITC – VA-6200MS EVAC Extension Controller

Brand Name:  ITC
Part Number: VA-6200MS
Product Type:  ITC – VA-6200MS EVAC Extension Controller
Specification: Please refer to the Datasheet on the Manufacturer’s Datasheet
Warranty: Manufacturer Standard Warranty
  Enquire Now
Compare
SKU: VA-6200MS Categories: , , Tags: , ,

Description

ITC – VA-6200MS EVAC Extension Controller

DETAILS:

ITC – VA-6200MS EVAC Extension Controller

Descriptions:

The ITC VA-6200MS is an EVAC (Emergency Voice Alarm Communication) Extension Controller designed to work in conjunction with the VA-P8500S amplifier.

Features:

  • With fault self-check of power-on system, and fault full check of manual system function.
  • With real-time indication of system status.
  • Automatically monitor every zone speaker loop status (open circuit, short circuit) in real-time.
  • Extension port can connect controller and next extension device.
  • The partition output has three-wire and four-wire forced-cut adjustment functions;
  • With fault self-check of power-on system, and fault full check of manual system function.
  • With real-time indication of system status.
  • Automatically monitor every zone speaker loop status (open circuit, short circuit) in real-time.
  • 8-channel short-circuit/level trigger mode, the trigger response can be configured with 3 different channels of EVAC, ALERT, and LINE3, and the output can be arbitrarily configured with partition, group, and short-circuit contact combination.
  • Extension port can connect controller and next extension device.
  • The partition output has three-wire and four-wire forced-cut adjustment functions

Specifications:

Model VA-6200MS
Rated Power Output 500W
Output Voltage 100V
MIC1-2 Input Distortion <1% (output rating), 1KHz
MIC1-2 Input Frequency Response 80Hz~20KHz
MIC1-2 Input Sensitivity 5mV/6/600Ω
MIC1-2 Input SNR >65dB
AUX3-6 Input Distortion <1% (output rating), 1KHz
AUX3-6 Input Frequency Response 80Hz~20KHz
AUX3-6 Input Sensitivity 350mV/10kΩ
AUX3-6 Input SNR >70dB
Spare Amplifier Input 100V
Spare Amplifier Audio Signal Output ±385mV (balanced output)
Alarm Input 8
Alarm Output 8
Zone Input 8
24V Relay Output 8
Short Circuit mode short circuit
Type of cooling air-cooled
Guard mode delay/overheat/ short circuit/ overload
Output Volume Control 6
Supply Voltage ~ 220V-240V, 50/60Hz
Maximum Current 3A
Fuse Size 250V/5A, slow type
Spare Voltage 24V DC, ±20%
Maximum Current 30A
Maximum Power Consumption 600W
Dimensions (L x W x D) 484 x 88 x 353mm
Weight 10.5kg
Installation method Desktop or 19″ cabinet

 

Additional information

Power (Mega Watt)

120 MW, 240 MW, 350 MW, 500 MW

Brand

ITC

Reviews

There are no reviews yet.

Be the first to review “ITC – VA-6200MS EVAC Extension Controller”
No more offers for this product!

General Inquiries

There are no inquiries yet.