Ramcro – RS-485, 2 Pr #24 Str TC, PO Ins, OS+TC Brd, LSZH Jkt, Dca

Brand Name:  RAMCRO
Part Number: R1319
Product Type:  Ramcro – Security & Sound (#18-4c-BC-CMR)
Specification: Please refer to the Datasheet on the Manufacturer’s Datasheet
Warranty: Manufacturer Standard Warranty
  Enquire Now
Compare

Description

Ramcro – RS-485, 2 Pr #24 Str TC, PO Ins, OS+TC Brd, LSZH Jkt, Dca

Details:

Ramcro – RS-485, 2 Pr #24 Str TC, PO Ins, OS+TC Brd, LSZH Jkt, Dca

Specifications:

The Ramcro cable is an alternative to the Belden cable

RS-485, 2 Pair 24AWG (7×32) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, LSZH Outer Jacket, CPR Dca

Technical Specifications

Product Overview

  • Suitable Applications: RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. Physical Characteristics (Overall)

Conductor

  • Size: 24
  • Stranding: 7×32
  • Material: TC – Tinned Copper

 

Insulation

  • Material: PE – Polyethylene
  • Insulation Diameter: 1.73 mm (0.0681 in)
  • Color Code: White/Blue & Blue/White, White/Orange & Orange/White

Outer Shield

  • Type: Tape, Braid
  • Material: Bi-Laminate (Alum+Poly), Tinned Copper (TC)
  • Material Trade Name: Beldfoil®
  • Coverage [%]: 100%, 90%
  • Drainwire Type: 24 AWG (7×32) TC

 

Outer Jacket

  • Material: LSZH – Low Smoke Zero Halogen (Flame Retardant), Table Notes: UV Stabilised, Overall Cable Diameter (Nominal): 8.65 mm (0.341 in)
  • Thickness: 0.9 mm (0.035 in)
  • Diameter – 8.65 mm (0.341 in)

Electrical Characteristics

Electricals

  • Conductor DCR: 78.7 Ohm/km (24.0 Ohm/1000ft), Nom. Outer Shield DCR: 7.2 Ohm/km (2.2 Ohm/1000ft)
  • Capacitance Cond-to-Cond: ) 42 pF/m (13 pF/ft)
  • Capacitance Cond-to-Other (Conds + Shield): 75.5 pF/m
  • Characteristic Impedence: 120 Ohm
  • Velocity of Prop: 66%
  • Current: 2.1 Amps per Conductor

High Frequency (Nominal/Typical)

  • Frequency [MHz]: 1
  • Insertion Loss (Attenuation): 1.97 dB/100m

Mechanical Characteristics

Temperature

  • Operating: -45°C To +80°C
  • Installation: -15°C To +80°C
  • Storage: -45°C To +80°C

Bend Radius

  • Stationary Min: 43 mm (1.7 in), Max Pull Tension, Bulk Cable Weight
  • Installation Min: 86 mm (3.4 in), : 395 N (88.8 lbf), 49 lbs/1000ft

Brand

Ramcro

Reviews

There are no reviews yet.

Be the first to review “Ramcro – RS-485, 2 Pr #24 Str TC, PO Ins, OS+TC Brd, LSZH Jkt, Dca”
No more offers for this product!

General Inquiries

There are no inquiries yet.