Ramcro – Security & Sound 2 Conductor 22 AWG BC Shielded CMR
Brand Name: | RAMCRO |
Part Number: | R1226 |
Product Type: | Ramcro – Security & Sound 2 Conductor 22 AWG BC Shielded CMR |
Specification: | Please refer to the Datasheet on the Manufacturer’s Datasheet |
Warranty: | Manufacturer Standard Warranty |
Description
Ramcro – Security & Sound 2 Conductor 22 AWG BC Shielded CMR
Details:
Ramcro – Security & Sound 2 Conductor 22 AWG BC Shielded CMR
Specifications:
The Ramcro cable is an alternative to the Belden cable
Security & Sound Cable, Riser-CMR, 2-22 AWG stranded bare copper conductors with polypropylene insulation, Beldfoil® shield and PVC jacket with ripcord
Technical Specifications
Product Overview
- Suitable Applications: Security System, Intercom/PA, Audio/Speaker, Noisy Environment
Construction Details
Conductor
- Element: Conductor(s)
- of Elements: 2
- Size: 22 AWG
- Stranding: 7×30
- Material: BC – Bare Copper
Insulation
- Element: Conductor(s)
- Material: PO – Polyolefin
- Thickness: 0.008 in (0.20 mm)
- Insulation Diameter: 0.045 in (1.1 mm)
- Color Code: Black, Red
Outer Shield
- Shield Type: Tape
- Material: Bi-Laminate (Alum+Poly)
- Coverage: 100%
- Drain wire Type: 24 AWG (7×32) TC
Outer Jacket
- Material: PVC – Polyvinyl Chloride
- Thickness: 0.017 in (0.43 mm)
- Diameter: 0.126 in (3.20 mm)
- Ripcord: Yes
- Overall Cable Diameter (Nominal): 0.188 in (3.20 mm)
Electrical Characteristics
Electricals
- Element: Conductor(s)
- Conductor DCR: 16.9 Ohm/1000ft
- Capacitance Cond-to-Cond: 34.5 pF/ft (113 pF/m)
- Capacitance Cond-to-Other (Conds + Shield): 62 pF/ft (200 pF/m)
- Current: 6 Amps per conductor @ 25°C
Voltage
- UL Voltage Rating: 300 V (CMR)
Mechanical Characteristics
Temperature
- UL Temperature: 75°C
- Operating: -20°C to +75°C
Bend Radius
- Stationary Min.: 1.3 in (33 mm)
- Installation Min.: 1.3 in (33 mm)
- Pull Tension: 23.7 lbs (10.8 kg)
- Bulk Cable Weight: 10 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor – Riser, Indoor
- Flammability / Reaction to Fire: UL 1666 Riser, FT4, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: Article 800, CMR
- CEC / C(UL) Compliance: CMG
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
- Plenum Number: 6500FH